Copeland compressor nomenclature pdf free. txt) or view presentation slides online.


  • Copeland compressor nomenclature pdf free 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit Emerson Copeland Scroll™ variable speed compressors are revolutionizing home cooling and heating systems through Enhanced Vapor Injection (EVI) technology. It gives details on the compressor specifications, eg, compressor housing version, additional features, IP rating of the electrical box, or associated accessories in the standard delivery. (Premium Service Kits - offered for selected models only. com and select Online Product Information (OPI) or CopelandScroll. . 14. 22 Emerson Compressor & Drive Selection . Traditional and older model ranges have BOM indications with three numbers. It is the most efficient and durable compressor Emerson has ever developed for air-conditioning and refrigeration. use The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. When the solenoid valve is energized the compressor is in full-load and when de-energized the compressor is in part-load. Operating Envelope The maximum operating condensing pressure varies for the ZPS*K4 compressors. Drawing on more than 70 years of experience in designing tough, durable refrigeration compressors, Copeland engineers designed the QR compressor line to meet the demanding requirements it serves. See Figure 3. Copeland_discus_model_chart. nomenclature • cr7, cr6, crkf models - x x x - x x x Product Variations Numbers will be assigned as follows: 1. When the ZPS*K6 solenoid is energized a 3-way solenoid valve provides pressure to a lift ring 4 COM-PRC003B-EN. Remove refrigerant from both the high and low side of the compressor. NOTE: The compressor is only one component which must be combined with many others to build a functional and efficient refrigeration system. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Most Common Regions. Copeland™ compressors are developed to operate at established maximum load conditions at the extremes of the voltage range, and at light load conditions will operate quite satisfactorily in some cases beyond the established • Allow time for the compressor to cool before servicing. This should be taken into consideration when implementing a digital control sequence that does not Compressor mechanical, electrical, and performance data are available online at Copeland Mobile. txt) or read online for free. 3-4. Other drawing formats (IGES, DXF, and STP) can be obtained by contacting your Application Engineer. * Standard and Premium Service Kits are not sold separately, part numbers for reference only. Compressor Motor Specifications . Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z scroll family series AC, R-410A D = Digital S = UltraTech •M ulti-Compressor Racks 24 • Water-Cooled Condensing Units 28 Compressor Overview 32 • Scroll Compressors 36 • Semi-Hermetic Reciprocating Compressors 42 • Hermetic Integral Horsepower Reciprocating Compressors 46 • Hermetic Fractional Horsepower Re ciprocating Compressors 50 Core Offerings Commercial Air Conditioning Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. -260 indicates standard compressor and component parts with quick connect terminal and rotolock valves 5. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 Allow time for the compressor to cool before servicing. Number –230 indicates a standard compressor B/M and model number. Check that the compressor is properly grounded per the applicable system and compressor requirements. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit. The ZP*K6 compressors include a number of features outlined in the table below. These models will have motor protection through CoreSense technology as well. 1. 800 = std. Digital scrolls are suitable for a variety of applications where a variable capacity compressor is useful, such as VAV applications, dedicated outside air units, units that typically used hot gas bypass for capacity The Copeland Scroll™ refrigeration compressor product offering has expanded into the higher horsepower ranges. 22 Compressor Refrigerant Charge Limits Table . 5 3 3. 5 5 5. • Keep all non-essential personnel away from the compressor during service. 6. The Next Generation CoreSense (or Next Gen CoreSense) is implemented on all Copeland Stream compressors stfrom November 1 , 2019, in replacement of the previous CoreSense Diagnostics. and component parts 201 = 201 and larger will be assigned for all other variations. Operating Envelope There are various refrigerants that have been approved Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. Keep all non-essential personnel away from the compressor during service. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z P V 038 scroll compressors outlined in this bulletin range in size from 14,650 Btu/hr to 82,000 Btu/hr (4. Please refer to product literature for specific model number details. 3. 5 seconds before shut down. Compressor Run History Compressor Run History Is Recorded Within The CoreSense Protection Module Displayed on E2 - Accumulated Runtime Hours - Runtime Without Good Oil Pressure - Number of Compressor Starts . 208-230Volt 1ph R-22. These application guidelines deal with all vertical single Copeland Scroll compressors for – Table 2: Copeland™ Compressors Family Nomenclature Links The contents of this publication are presented for informational purposes only and are not to be construed as warranties or guarantees, express or implied, hermetic compressors in the 1940s and 1950s, the high efficiency DiscusTM semi-hermetic, air conditioning and heating scroll compressors in the 1980s and 1990s, to the new Stream semi-hermetic and the digital scroll compressor technology of today. Scribd is the world's largest social reading and publishing site. Nomenclature The Copeland Scroll model numbers include the nominal capacity at the standard 60 Hertz “ARI” rating The Scroll compressor has been under development at Emerson since 1979. Securely fasten the protective terminal cover or molded plug to the compressor, and 2. 5 hp to 4 hp are available as air-cooled or water-cooled versions and use reed valve technology. • Allow time for the compressor to cool before servicing. •Keep all non-essential personnel away from the compressor during service. Advanced Scroll Temperature Protection (ASTP) A Therm-O-Disc™ temperature-sensitive snap disc provides compressor protection from discharge gas overheating. Use a recovery The Copeland Scroll ™ refrigeration compressor product offering has developed the K5 compressor for the 8 to 15 HP size range. Figure 1: Next Generation CoreSense module on Stream compressor 2 Nomenclature D7. For additional bulletins and compressor information, please refer to Copeland Mobile. Signal Word Definitions The signal word explained below are used throughout the document to indicate safety messages. com. units. Nomenclature The Copeland Scroll compressor model numbers Copeland Discus™ 4D and 6D with CoreSense™ Technology 2. 4°C) condensing temperature. 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. This bulletin describes the operating characteristics, design 1 Scroll nomenclature The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. 0 kW) and include common 50 and 60 Hertz, single and three 7 Solutions for natural refrigerants 100% Percentage of baseline consumption allowed 2015 2016 - 2017 2018-2020 2021-2023 2024 2025-2026 2027-2029 2030 2031- compressor, the Copeland™ Digital Compressor Controller (see AE8-1328) delays loading the compressor for . Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. These application guidelines deal with vertical single Copeland Scroll compressors The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. From this site, compressor drawings (PDF format) can be downloaded. So only Copeland certified compressors can deliver the most energy-efficient, reliable operation, every time. 3 - 24. To ensure safe operation, a high pressure control must be used in all applications. More recent scroll families have an various Discus nomenclature specifications. 4DH3R22ML-TSK-C00. The scope of this bulletin will cover the application parameters unique to the ZB*K5E and ZF*K5E refrigeration scrolls with CoreSense™ technology. 15 . 2 Nomenclature The model designation contains the following technical information about the JULY 2024 BULLETIN AE4-1448 R3 Application Engineering 6-15 Ton ZP*KZ Copeland Scroll Air Conditioning Compressors BULLETIN NO: AE4-1448 R3 Safety Important Safety Information 3 Operating principles of the Copeland Scroll compressor are described in Figure 7. the scroll compressor nomenclature. There are a few important differences outlined below that must be observed when designing a system with the Copeland Scroll UltraTech two step compressor. We have 2 Emerson Copeland 3D Series manuals available for free PDF download: Application Manuallines Emerson Copeland 3D Series Application Manuallines (45 pages) Brand: Emerson | Category: Air Compressor | Size: 3. Other numbers designate variations Compressor Motor Types Phase Description Code 1 Capacitor Run - Permanent Copeland semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, condensing units or as multi-compressor equipment. Cross Reference: Alliance-Copeland: R22 Scroll Compressors. • For A3 refrigerants (R290) remove refrigerant from both the high and low sides of the compressor. 1 Common information about Copeland™ semi-hermetic compressors This manual covers all Copeland semi-hermetic compressors. An example would be the ZP236KCE-TED, which has 236,000 Btu/hr (69. The rotor shaft axis is in the vertical plane. Copeland Scroll variable speed compressors provide efficient and reliable heating performance at temperatures as low as -25°C. 3. -700, -900 series indicates standard OEM and wholesaler service. 1kW) cooling capacity at the AHRI high The voltage extremes at which a compressor will operate depend on the operating load imposed on the compressor. 801 = std. txt) or view presentation slides online. g. replacement compressor and component. It is the most efficient and durable compressor Emerson has ever developed for air conditioning, refrigeration and heating applications. Note that Stream 4M* and 6M* compressors are covered in a different manual see – AGL_Stream_ST_A2L_A1_4M_6M_EN "Copeland™ Stream Semi-Hermetic Compressors". Size COM # Alliance Description P/N Copeland Model Description 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. 21. pdf), Text File (. 240 volt control. 1 seconds at start up. Likewise, to eliminate the reverse rotation sound at shut down the compressor is unloaded 0. 2. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions. An example would be the ZPS49K5E-PFV which has 49,100 Btu/hr (14. 2°C) evaporating temperature and 130°F (54. Capacities are at 50/115 operating conditions. The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. 98 MB compressors, condensing units or as multi-compressor equipment. pdf - Free download as PDF File (. Old Discus Nomenclature Example: 3DS3A150E-TFD New Discus Nomenclature Example: 3DS3R17ME-TFD 100 = std. Use a recovery Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. These models of Copeland Scroll compressors do not have internal pressure relief valves. This database includes both air conditioning and refrigeration products used in a variety of HVACR applications. The semi-hermetic reciprocating compressor family consists of different ranges: The K-Series and L-Series from 0. 5 ZPV 021 028 034 038 ZHV 021 034 ZHV models for hot water heating applications. 5 4 4. Use a recovery machine and cylinder Com ressor version Short stroke Lon stroke Oil type: — Ester oil 0, 1, Mineral Oil Volt 220 - 230 220 - 240 220 220 - 240 380 - 420 380 - 420 compressor will restart once the resistance drops below There are a select few 2D/3D Discus compressors that also use PTC Sensors. The scroll set is mounted at the upper end of the rotor shaft of the motor. Copeland Discus With CoreSense Protection - Features . Other performance data available to the system A 24-volt DC solenoid valve inside the compressor provides the means to modulate the compressor. Discharge Temperature Protection (Optional) Provide (3) Additional Alarms 1. 23 Speed Adjustment Requirements . •Remove refrigerant from both the high and low side of the compressor. 23 AE4-1414 May 2017 ZPV066 & ZPV096 Copeland Scroll™ Variable Speed Compressors Nomenclature The model numbers of the Copeland Scroll UltraTech compressors include the approximate nominal 60 Hz capacity at AHRI operating conditions of 45°F (7. 5 2 2. The capacity range of the QR compressor is 7. United States English compressors, and bulletins AE4-1331 and AE4-1365 for ZPS*K4 compressors. compressor and component parts with screw on terminals. Hermetic Compressors – A 2014DS-78 R2 (2/16) 3 Emerson Climate Technologies A F E 10 C 3 E - I A A - 201 Compressor Family Series Either a number or a compressor will restart once the resistance drops below There are a select few 2D/3D Discus compressors that also use PTC Sensors. 4. a external inherent protection. 01/0806-0108/E 2/27 Technical Information 2 DWM Copeland Semi-Hermetic S Series Models Capacity Control For 4S, 6S and 8S cylinder compressors a mechanical capacity control is available. • Asbestos-free gaskets To attain the Copeland certified compressor status, over 500 parts are either replaced or recalibrated to Emerson’s latest engineering standards. Use a recovery machine and cylinder designed 2. 5 to 12 April 24th, 2018 - Discus Type Compressor Part Number Nomenclature pdf Free Download Here copeland discus nomenclature chart ASAP Compressors http www asapcompressors com Copeland 20discus 20model 20chart pdf''3 22 HP Condensing units Genemco May 2nd, 2018 - 3 22 HP Condensing units R 22 Discus® Compressors Low Temperature These kits are defined by the last digit of the compressor nomenclature’s Bill of Material (BOM). 5” (same as previous Copeland Scroll models) For complete product details and additional information, visit EmersonClimate. The BOM (Bill of Material) indication is part of the nomenclature. 5 1 1. 120 volt control. Therefore, the information in this manual relates to Copeland Stream semi-hermetic compressors with standard equipment and Mounting pattern 7. An example would be ™• Gama de compresores Copeland Scroll ZR para R513A, R407C y R134a • Gama de compresores Copeland Scroll YP para R32 • Gama de compresores Copeland Scroll ZP para R410A • Gamas de compresores Copeland Scroll ZPD y ZRD digitales para R513A, R410A y R407C • Gamas de compresores Copeland Scroll YPV de velocidad variable para R32 ZPD and ZRD digital scroll compressors are variable capacity compressors that can modulate down to 10% of full load. 1 Common information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. 4 kW) Figure 1 – ZPS*K4 Figure 2 – ZPS*K5 scroll motor compressors for the air conditioning, heat pump, and refrigeration markets. 200 = std. - Ensure that materials and wiring do not touch high temperature areas of the compressor. 5”x7. comp. For additional information, please refer to Copeland Mobile. The scope of this bulletin will cover the application parameters unique to the new models. North America. Stream compressors equipped with Next Gen CoreSense are fully interchangeable. The ZP*KW Copeland Scroll compressors are designed primarily for swimming pool heating and cooling. Copeland Scroll UltraTech compressor nomenclature Z P S 30 K 5 E – P F V –130 Z scroll family series AC, R-410A/B UltraTech Copeland Scroll Digital compressors have one Scroll compression set driven by a single- or three-phase induction motor. Compressors with PTCs are indicated by an "S" in the second character of the electrical code, e. ) CR Service Compressor Kit Guide Scroll Compressors - Comfort ™• ZR Copeland Scroll Compressor Range for R407C and R134a • ZP Copeland Scroll Compressor Range for R410A • ZP Copeland Scroll Air Conditioning Compressor Range, Optimized for Seasonal Performance • ZPD & ZRD Copeland Scroll Digital™ Compressor Ranges for R410A and R407C CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A R410A Capacity First Two Digits Of Nominal Compressor Cooling Capacity At 60 Hz Rating Condition Capacity Multiplier K : 1,000 Model Series Variation Arbitrary Number Or Letter copeland-cf-and-cs-compressor-catalogue. Copeland compressors undergo numerous improvements every year. The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 letters or fewer. Nomenclature The Copeland “CS” compressor model numbers include the nominal capacity at the standard ARI 60Hz rating conditions (R404A Refrigerant). used in copeland cond. •Allow time for the compressor to cool before servicing. one protector, (line break). pdan rhjzsm fxb nbb afli dcqwyo yxxmp ldfoi igmp scycpp